| Assessment Year | 2005 |
|---|---|
| Principal Product | Fruit and vegetable juices, beverages, and products. |
| NAICS | 311421: Fruit and Vegetable Canning |
| SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
| Sales Range | $50 M to 100M |
| # of Employees | 350 |
| Plant Area |
463,000
ft2
|
| Annual Production | 18,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $944,292 | 12,760,700 |
kWh
|
$0.074 |
| Electricity Demand | $277,918 | 30,983 |
kW-mo/yr
|
$8.97 |
| Natural Gas | $837,115 | 1,356,750 |
MMBtu
|
$0.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $248,045 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $158,359 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,549 | - |
$2,047
27,666
kWh
|
$502
-
kW-mo/yr
|
- | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $71,711 | $7,200 |
$14,358
194,027
kWh
|
$4,853
-
kW-mo/yr
|
- | $52,500 | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,385 | $1,250 |
$5,237
70,774
kWh
|
$1,148
-
kW-mo/yr
|
- | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $9,644 | $1,626 |
$7,967
107,658
kWh
|
$1,677
-
kW-mo/yr
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,067 | $1,456 |
$508
6,867
kWh
|
$81
-
kW-mo/yr
|
- | $1,478 | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $137,714 | $144,177 | - | - |
$137,714
-
MMBtu
|
- | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,975 | $26,200 |
$13,696
185,079
kWh
|
$4,279
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $248,045 | $181,909 |
$43,813
592,071
kWh
|
$12,540
-
kW-mo/yr
|
$137,714
-
MMBtu
|
$53,978 | ||
| TOTAL IMPLEMENTED | $158,359 | $148,509 |
$15,759
212,965
kWh
|
$3,408
-
kW-mo/yr
|
$137,714
-
MMBtu
|
$1,478 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs