| Assessment Year | 2011 | 
|---|---|
| Principal Product | Shellfish Larvae | 
| NAICS | 112512: Shellfish Farming | 
| SIC | 0921: Fish Hatcheries and Preserves | 
| Sales Range | $500 k  to 1M  | 
    
| # of Employees | 6 | 
| Plant Area | 
                            20,000
                 
ft2
 
                     | 
    
| Annual Production | 6,000,000,000
             
units
 
         | 
    
| Production Hrs. Annual | 6,720
             
hrs
 
         | 
    
| Location (State) | Oregon | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $18,612 | 377,200 | 
             
kWh
 
         | 
        $0.049 | 
| Electricity Demand | $657 | 765 | 
             
kW-mo/yr
 
         | 
        $0.86 | 
| LPG | $23,822 | 991 | 
             
MMBtu
 
         | 
        $24.04 | 
| Fuel Oil #2 | $107,932 | 4,604 | 
             
MMBtu
 
         | 
        $23.44 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $120,914 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $10,860 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Administrative Changes Savings | 
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1113: Reduce combustion air flow to optimum | $10,860 | $1,000 | - | - | 
                        $1,290
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                
                        $10,570
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                $(-1,000.0) | |
| 02 | 2.2444: Use hot process fluids to preheat incoming process fluids | $109,290 | $104,251 | 
                        $(-7,400.0)
                                                     (-150,000)
                                 
                                            
kWh
 
                             | 
                                                                                
                        $(-210.0)
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | 
                        $116,900
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | |
| 03 | 2.9114: Use solar heat to make electricty | $764 | $4,960 | - | - | - | 
                        $764
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | |
| TOTAL RECOMMENDED | $120,914 | $110,211 | 
                        $(-7,400.0)
                                                     (-150,000)
                                 
                                            
kWh
 
                             | 
                                                                                
                        $(-210.0)
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                
                        $1,290
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                
                        $128,234
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                $(-1,000.0) | ||
| TOTAL IMPLEMENTED | $10,860 | $1,000 | - | - | 
                        $1,290
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                
                        $10,570
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                $(-1,000.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs