Assessment Year | 2011 |
---|---|
Principal Product | Shellfish Larvae |
NAICS | 112512: Shellfish Farming |
SIC | 0921: Fish Hatcheries and Preserves |
Sales Range | $500 k to 1M |
# of Employees | 6 |
Plant Area |
20,000
ft2
|
Annual Production | 6,000,000,000
units
|
Production Hrs. Annual | 6,720
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $18,612 | 377,200 |
kWh
|
$0.049 |
Electricity Demand | $657 | 765 |
kW-mo/yr
|
$0.86 |
LPG | $23,822 | 991 |
MMBtu
|
$24.04 |
Fuel Oil #2 | $107,932 | 4,604 |
MMBtu
|
$23.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $120,914 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,860 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1113: Reduce combustion air flow to optimum | $10,860 | $1,000 | - | - |
$1,290
-
MMBtu
|
$10,570
-
MMBtu
|
$(-1,000.0) | |
02 | 2.2444: Use hot process fluids to preheat incoming process fluids | $109,290 | $104,251 |
$(-7,400.0)
(-150,000)
kWh
|
$(-210.0)
-
kW-mo/yr
|
- |
$116,900
-
MMBtu
|
- | |
03 | 2.9114: Use solar heat to make electricty | $764 | $4,960 | - | - | - |
$764
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $120,914 | $110,211 |
$(-7,400.0)
(-150,000)
kWh
|
$(-210.0)
-
kW-mo/yr
|
$1,290
-
MMBtu
|
$128,234
-
MMBtu
|
$(-1,000.0) | ||
TOTAL IMPLEMENTED | $10,860 | $1,000 | - | - |
$1,290
-
MMBtu
|
$10,570
-
MMBtu
|
$(-1,000.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs