Assessment Year 2005
Principal Product Cellulose Insulation
NAICS 322299: All Other Converted Paper Product Manufacturing
SIC 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 25
Plant Area 19,000
ft2
Annual Production 1,500,000
pieces
Production Hrs. Annual 3,744
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $34,093 531,775
kWh
Electricity Demand $64,086 6,060
kW-mo/yr
Electricity Fees $13,609 -
Natural Gas $5,407 591
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,274 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,052

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $206 - $133
2,059
kWh
$73
-
kW-mo/yr
-
02 2.8114: Change rate schedules or other changes in utility service $2,133 - - - $2,133
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,791 $477 $1,178
18,121
kWh
$613
-
kW-mo/yr
-
04 2.4314: Use synthetic lubricant $2,489 $2,000 $1,633
25,122
kWh
$856
-
kW-mo/yr
-
05 2.6122: Adjust vents to minimize energy use $21,600 $21,422 - - $21,600
06 2.4221: Install compressor air intakes in coolest locations $55 $92 $34
524
kWh
$21
-
kW-mo/yr
-
TOTAL RECOMMENDED $28,274 $23,991 $2,978
45,826
kWh
$1,563
-
kW-mo/yr
$23,733
TOTAL IMPLEMENTED $2,052 $569 $1,345
20,704
kWh
$707
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs