| Assessment Year | 2004 |
|---|---|
| Principal Product | Hardwood Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
37,000
ft2
|
| Annual Production | 10,000,000
thousand feet
|
| Production Hrs. Annual | 2,470
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $164,424 | 3,663,788 |
kWh
|
$0.045 |
| Electricity Demand | $131,507 | 15,007 |
kW-mo/yr
|
$8.76 |
| Electricity Fees | $7,125 | - |
|
- |
| Natural Gas | $6,610 | 1,738 |
MMBtu
|
$3.80 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $99,923 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,227 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,315 | - |
$676
15,017
kWh
|
$639
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,691 | $150 |
$868
19,291
kWh
|
$823
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,644 | $500 |
$847
18,821
kWh
|
$797
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4314: Use synthetic lubricant | $1,315 | $2,000 |
$676
15,028
kWh
|
$639
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $482 | $1,330 |
$377
8,387
kWh
|
$105
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.3212: Optimize plant power factor | $5,577 | $30,560 | - | - | $5,577 | - | - | |
| 07 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $87,899 | $535,000 |
$164,424
3,663,788
kWh
|
$131,461
-
kW-mo/yr
|
- |
$6,604
-
MMBtu
|
$(-214,590.0) | |
| TOTAL RECOMMENDED | $99,923 | $569,540 |
$167,868
3,740,332
kWh
|
$134,464
-
kW-mo/yr
|
$5,577 |
$6,604
-
MMBtu
|
$(-214,590.0) | ||
| TOTAL IMPLEMENTED | $10,227 | $31,210 |
$2,391
53,129
kWh
|
$2,259
-
kW-mo/yr
|
$5,577 | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs