Assessment Year | 2004 |
---|---|
Principal Product | Small Package Pesticides |
NAICS | 325320: Pesticide and Other Agricultural Chemical Manufacturing |
SIC | 2879: Pesticides and Agricultural Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
220,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $91,809 | 1,111,745 |
kWh
|
$0.083 |
Electricity Demand | $61,413 | 4,102 |
kW-mo/yr
|
$14.97 |
Natural Gas | $49,974 | 6,072 |
MMBtu
|
$8.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,816 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,131 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,721 | - |
$1,538
18,536
kWh
|
$1,183
-
kW-mo/yr
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $2,094 | $142 |
$1,181
14,226
kWh
|
$913
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,555 | $617 |
$881
10,620
kWh
|
$674
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $673 | $461 |
$244
2,943
kWh
|
$60
-
kW-mo/yr
|
$369 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,182 | $3,211 |
$4,017
48,399
kWh
|
$165
-
kW-mo/yr
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,591 | $20,054 |
$5,142
61,956
kWh
|
$5,449
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $21,816 | $24,485 |
$13,003
156,680
kWh
|
$8,444
-
kW-mo/yr
|
$369 | ||
TOTAL IMPLEMENTED | $9,131 | $4,289 |
$6,680
80,498
kWh
|
$2,082
-
kW-mo/yr
|
$369 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs