| Assessment Year | 2004 |
|---|---|
| Principal Product | Manufacturing Food Services |
| NAICS | 339999: All Other Miscellaneous Manufacturing |
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 48 |
| Plant Area |
112,000
ft2
|
| Annual Production | 587,786,000
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $39,138 | 462,794 |
kWh
|
$0.085 |
| Electricity Demand | $20,540 | 1,377 |
kW-mo/yr
|
$14.92 |
| Electricity Fees | $7,829 | - |
|
- |
| Natural Gas | $27,868 | 29,606 |
MMBtu
|
$0.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,796 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $1,858 | - | - | - | - | $1,858 | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,779 | - |
$884
11,050
kWh
|
$895
-
kW-mo/yr
|
- | - | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $2,396 | - |
$1,188
14,851
kWh
|
$1,208
-
kW-mo/yr
|
- | - | |
| 04 | 2.4314: Use synthetic lubricant | $1,343 | $200 |
$672
8,398
kWh
|
$671
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $942 | $363 |
$465
5,812
kWh
|
$477
-
kW-mo/yr
|
- | - | |
| 06 | 2.2437: Recover waste heat from equipment | $489 | $304 | - | - |
$489
-
MMBtu
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,158 | $2,415 |
$576
7,205
kWh
|
$582
-
kW-mo/yr
|
- | - | |
| 08 | 2.4226: Use / purchase optimum sized compressor | $4,989 | $10,421 |
$2,482
31,028
kWh
|
$2,507
-
kW-mo/yr
|
- | - | |
| 09 | 2.2414: Use waste heat from hot flue gases to preheat | $3,340 | $10,000 | - | - |
$3,340
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $18,294 | $23,703 |
$6,267
78,344
kWh
|
$6,340
-
kW-mo/yr
|
$3,829
-
MMBtu
|
$1,858 | ||
| TOTAL IMPLEMENTED | $13,796 | $11,288 |
$5,691
71,139
kWh
|
$5,758
-
kW-mo/yr
|
$489
-
MMBtu
|
$1,858 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs