Assessment Year | 2004 |
---|---|
Principal Product | Newspaper Publishing |
NAICS | 511110: Newspaper Publishers |
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
62,080
ft2
|
Annual Production | 30,000,000
pieces
|
Production Hrs. Annual | 5,148
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,786 | 943,840 |
kWh
|
$0.046 |
Electricity Demand | $28,927 | 1,942 |
kW-mo/yr
|
$14.90 |
Natural Gas | $14,979 | 1,735 |
MMBtu
|
$8.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,813 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,523 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $1,548 | - |
$743
16,146
kWh
|
$805
-
kW-mo/yr
|
- | - | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $3,782 | - | - | - | - | - | $3,782 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $205 | - |
$116
2,523
kWh
|
$89
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $891 | $180 |
$504
10,965
kWh
|
$387
-
kW-mo/yr
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $97 | $108 |
$52
1,133
kWh
|
$45
-
kW-mo/yr
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $361 | $500 |
$29
630
kWh
|
$15
-
kW-mo/yr
|
- | $264 | $53 | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,329 | $3,430 |
$703
15,288
kWh
|
$626
-
kW-mo/yr
|
- | - | - | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $3,600 | $19,500 | - | - |
$3,600
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $11,813 | $23,718 |
$2,147
46,685
kWh
|
$1,967
-
kW-mo/yr
|
$3,600
-
MMBtu
|
$264 | $3,835 | ||
TOTAL IMPLEMENTED | $6,523 | $288 |
$1,415
30,767
kWh
|
$1,326
-
kW-mo/yr
|
- | - | $3,782 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs