| Assessment Year | 2004 |
|---|---|
| Principal Product | Metal Rings |
| NAICS | 331511: Iron Foundries |
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $10 M to 50M |
| # of Employees | 67 |
| Plant Area |
166,116
ft2
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,910 | 1,982,836 |
kWh
|
$0.049 |
| Electricity Demand | $94,925 | 8,378 |
kW-mo/yr
|
$11.33 |
| Electricity Fees | $1,121 | - |
|
- |
| Natural Gas | $370,178 | 71,307 |
MMBtu
|
$5.19 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $125,493 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $97,193 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 4.731: Advertise product or service | $83,900 | - | - | - | - | $83,900 | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,014 | - |
$2,008
41,068
kWh
|
$1,006
-
kW-mo/yr
|
- | - | |
| 03 | 2.6218: Turn off equipment when not in use | $331 | - |
$331
6,780
kWh
|
- | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,663 | $502 |
$997
20,384
kWh
|
$666
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,191 | $680 |
$793
16,225
kWh
|
$398
-
kW-mo/yr
|
- | - | |
| 06 | 2.2437: Recover waste heat from equipment | $18,502 | $12,517 | - | - |
$18,502
-
MMBtu
|
- | |
| 07 | 2.7135: Install occupancy sensors | $483 | $523 |
$336
6,864
kWh
|
$147
-
kW-mo/yr
|
- | - | |
| 08 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $11,288 | $16,817 | - | - |
$11,288
-
MMBtu
|
- | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,121 | $25,260 |
$3,070
62,783
kWh
|
$2,051
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $125,493 | $56,299 |
$7,535
154,104
kWh
|
$4,268
-
kW-mo/yr
|
$29,790
-
MMBtu
|
$83,900 | ||
| TOTAL IMPLEMENTED | $97,193 | $18,020 |
$1,460
29,869
kWh
|
$545
-
kW-mo/yr
|
$11,288
-
MMBtu
|
$83,900 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs