Assessment Year 2003
Principal Product transportation parts
NAICS 332912: Fluid Power Valve and Hose Fitting Manufacturing
SIC 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 160
Plant Area 241,969
ft2
Annual Production 350,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $235,284 4,842,000
kWh
Electricity Demand $55,762 9,360
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $147,820 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $40,125

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Water Consumption Savings One-time Revenue or Avoided Cost Savings
01 2.4221: Install compressor air intakes in coolest locations $5,012 $232 $4,255
69,960
kWh
$757
-
kW-mo/yr
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,388 $480 $4,430
88,612
kWh
$958
-
kW-mo/yr
- - -
03 4.425: Eliminate/reduce redundant inspections $28,125 $10,016 - - $28,125 - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $24,270 $24,797 $20,364
407,280
kWh
$3,906
-
kW-mo/yr
- - -
05 4.522: Modify storage space to avoid rental of a warehouse $24,000 $19,912 - - - - $24,000
06 2.3322: Use existing dam to generate electricity $49,025 $132,000 $39,600
792,000
kWh
$9,425
-
kW-mo/yr
- - -
07 2.7232: Replace existing hvac unit with high efficiency model $12,000 $68,560 - - - $12,000
-
Tgal
-
TOTAL RECOMMENDED $147,820 $255,997 $68,649
1,357,852
kWh
$15,046
-
kW-mo/yr
$28,125 $12,000
-
Tgal
$24,000
TOTAL IMPLEMENTED $40,125 $78,576 - - $28,125 $12,000
-
Tgal
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Water Consumption Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs