Assessment Year 2002
Principal Product Corrugated Boxes
NAICS 322211: Corrugated and Solid Fiber Box Manufacturing
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 128
Plant Area 200,000
ft2
Annual Production 430,000
thousand feet
Production Hrs. Annual 6,006
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $227,395 3,273,000
kWh
Electricity Demand $139,490 9,318
kW-mo/yr
Electricity Fees $8,164 -
Natural Gas $193,637 44,753
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,526 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2414: Use waste heat from hot flue gases to preheat $10,627 $14,850 n/a - - $10,627
-
MMBtu
02 2.7111: Reduce illumination to minimum necessary levels $6,105 $110 n/a $6,105
63,601
kWh
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,683 $10,300 n/a $5,683
82,362
kWh
- -
04 2.3212: Optimize plant power factor $5,043 $16,500 n/a - $5,043
-
kW-mo/yr
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,217 $160 n/a $4,217
60,250
kWh
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,659 $270 n/a $2,659
38,540
kWh
- -
07 2.4221: Install compressor air intakes in coolest locations $2,192 $103 n/a $2,192
31,781
kWh
- -
TOTAL RECOMMENDED $36,526 $42,293 $20,856
276,534
kWh
$5,043
-
kW-mo/yr
$10,627
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs