Assessment Year | 2001 |
---|---|
Principal Product | Theatrical Rigging Equipment |
NAICS |
n/a
|
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 43 |
Plant Area |
20,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $13,534 | 185,015 |
kWh
|
$0.073 |
Electricity Demand | $8,999 | 1,082 |
kW-mo/yr
|
$8.32 |
Electricity Fees | $1,378 | - |
|
- |
Natural Gas | $7,719 | 1,081 |
MMBtu
|
$7.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $183,832 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,673 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Primary Product Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $48 | - |
$48
-
kWh
|
- | - | - | |
02 | 4.122: Develop standard procedures to improve internal yields | $4,867 | $234 | - | - | - | $4,867 | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $758 | $1,323 | - |
$758
-
MMBtu
|
- | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $231 | $250 |
$231
3,104
kWh
|
- | - | - | |
05 | 4.445: Install equipment to move product | $30,000 | $34,762 | - | - | $30,000 | - | |
06 | 2.7135: Install occupancy sensors | $189 | $244 |
$189
3,435
kWh
|
- | - | - | |
07 | 4.426: Modify workload | $147,739 | $201 | - | - | $147,739 | - | |
TOTAL RECOMMENDED | $183,832 | $37,014 |
$468
6,539
kWh
|
$758
-
MMBtu
|
$177,739 | $4,867 | ||
TOTAL IMPLEMENTED | $5,673 | $1,557 |
$48
-
kWh
|
$758
-
MMBtu
|
- | $4,867 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Primary Product Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs