Assessment Year | 1985 |
---|---|
Principal Product | MOVEABLE DOLL EYES |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
n/a
|
Annual Production | 150,000
pieces
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $195,306 | 2,465,123 |
kWh
|
$0.079 |
Natural Gas | $981 | 102 |
MMBtu
|
$9.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,419 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,738 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,407 | $660 |
$4,407
55,686
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,466 | $48 |
$8,466
106,975
kWh
|
|
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $725 | $340 |
$725
9,086
kWh
|
|
04 | 2.4227: Use compressor air filters | $1,856 | $800 |
$1,856
23,447
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,009 | - |
$3,009
38,101
kWh
|
|
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $293 | $75 |
$293
3,810
kWh
|
|
07 | 2.4322: Use or replace with energy efficient substitutes | $22,663 | $60,000 |
$22,663
286,049
kWh
|
|
TOTAL RECOMMENDED | $41,419 | $61,923 |
$41,419
523,154
kWh
|
||
TOTAL IMPLEMENTED | $17,738 | $1,508 |
$17,738
224,209
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs