| Assessment Year | 1985 |
|---|---|
| Principal Product | MOVEABLE DOLL EYES |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 115 |
| Plant Area |
n/a
|
| Annual Production | 150,000
pieces
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $195,306 | 2,465,123 |
kWh
|
$0.079 |
| Natural Gas | $981 | 102 |
MMBtu
|
$9.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $41,419 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,738 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,407 | $660 |
$4,407
55,686
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,466 | $48 |
$8,466
106,975
kWh
|
|
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $725 | $340 |
$725
9,086
kWh
|
|
| 04 | 2.4227: Use compressor air filters | $1,856 | $800 |
$1,856
23,447
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,009 | - |
$3,009
38,101
kWh
|
|
| 06 | 2.6212: Turn off equipment during breaks, reduce operating time | $293 | $75 |
$293
3,810
kWh
|
|
| 07 | 2.4322: Use or replace with energy efficient substitutes | $22,663 | $60,000 |
$22,663
286,049
kWh
|
|
| TOTAL RECOMMENDED | $41,419 | $61,923 |
$41,419
523,154
kWh
|
||
| TOTAL IMPLEMENTED | $17,738 | $1,508 |
$17,738
224,209
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs