Assessment Year 1985
Principal Product ELECTRICAL CONTROLS
NAICS
n/a
SIC 3625: Relays and Industrial Controls
Sales Range $5
M
to 10
M
# of Employees 351
Plant Area
n/a
Annual Production 1,200,000
pieces
Production Hrs. Annual 2,023
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $311,731 2,498,535
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $60,678 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $39,547

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $8,841 $13,140 $8,841
70,633
kWh
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,014 $240 $5,014
40,152
kWh
-
03 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $2,300 $2,180 $2,300
18,464
kWh
-
04 2.6121: Reduce hot water temperature to the minimum required $106 - $106
879
kWh
-
06 2.1311: Replace electrically-operated equipment with fossil fuel equipment $177 $285 $224
1,758
kWh
$(-47.0)
-
MMBtu
07 2.2514: Cover open tanks $475 $400 - $475
-
MMBtu
08 2.7243: Improve air circulation with destratification fans / other methods $433 $700 $(-233.0)
(-2,052)
kWh
$666
-
MMBtu
09 2.1233: Analyze flue gas for proper air/fuel ratio $1,520 $537 - $1,520
-
MMBtu
10 2.2136: Install / repair insulation on steam lines $3,918 $3,089 - $3,918
-
MMBtu
11 2.2437: Recover waste heat from equipment $1,508 $350 - $1,508
-
MMBtu
12 2.7421: Reduce glazed areas in buildings $1,130 $4,848 - $1,130
-
MMBtu
13 2.7441: Replace broken windows and/or window sash $9,670 $136 - $9,670
-
MMBtu
14 2.7221: Lower temperature during the winter season and vice-versa $25,586 $3,500 - $25,586
-
MMBtu
TOTAL RECOMMENDED $60,678 $29,405 $16,252
129,834
kWh
$44,426
-
MMBtu
TOTAL IMPLEMENTED $39,547 $16,880 $13,961
111,664
kWh
$25,586
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs