ITAC Assessment: ST0034
ITAC logo
ITAC Assessment: ST0034
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1985
Principal Product AUDIO-VISUAL SYSTEMS
NAICS
n/a
SIC 3861: Photographic Equipment and Supplies
Sales Range $5
M
to 10
M
# of Employees 57
Plant Area
n/a
Annual Production 40,000
pieces
Production Hrs. Annual 2,214
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $23,315 199,590
kWh
Natural Gas $11,754 1,767
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,067 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,215

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,370 $639 $5,370
46,014
kWh
-
02 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $2,160 $80 $2,160
18,464
kWh
-
03 2.6121: Reduce hot water temperature to the minimum required $330 - $330
2,931
kWh
-
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $462 $870 $609
5,275
kWh
$(-147.0)
-
MMBtu
05 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $575 $1,200 $575
4,982
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $150 - $150
1,172
kWh
-
08 2.7494: Install storm windows and doors $574 $150 - $574
-
MMBtu
09 2.7221: Lower temperature during the winter season and vice-versa $2,171 - - $2,171
-
MMBtu
10 2.7446: Utilize sensors controlling roof and wall openings $333 $880 - $333
-
MMBtu
11 2.7444: Close holes and openings in building such as broken windows $942 $78 - $942
-
MMBtu
TOTAL RECOMMENDED $13,067 $3,897 $9,194
78,838
kWh
$3,873
-
MMBtu
TOTAL IMPLEMENTED $3,215 $1,280 $3,215
27,549
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs