Assessment Year | 1984 |
---|---|
Principal Product | STEEL FABRICATIONS |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 400,000
lb
|
Production Hrs. Annual | 2,875
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,436 | 182,005 |
kWh
|
$0.13 |
Natural Gas | $135 | 9 |
MMBtu
|
$15.00 |
Fuel Oil #2 | $5,727 | 700 |
MMBtu
|
$8.18 |
Fuel Oil #4 | $5,727 | 864 |
MMBtu
|
$6.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,550 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,550 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Fuel Oil #4 Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $599 | $537 | - |
$315
-
MMBtu
|
$284
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,185 | $200 |
$1,185
9,086
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,058 | $40 |
$1,058
8,206
kWh
|
- | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $583 | $1,480 | - | - |
$583
-
MMBtu
|
|
05 | 2.2136: Install / repair insulation on steam lines | $990 | $960 | - |
$520
-
MMBtu
|
$470
-
MMBtu
|
|
06 | 2.7441: Replace broken windows and/or window sash | $4,135 | $845 | - | - |
$4,135
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,550 | $4,062 |
$2,243
17,292
kWh
|
$835
-
MMBtu
|
$5,472
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,550 | $4,062 |
$2,243
17,292
kWh
|
$835
-
MMBtu
|
$5,472
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Fuel Oil #4 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs