| Assessment Year | 2026 |
|---|---|
| Principal Product | Chocolate covered macadamia nut candies |
| NAICS | 311352: Confectionery Manufacturing from Purchased Chocolate |
| SIC | 2064: Candy and Other Confectionery Products |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
65,000
ft2
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Hawaii |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $739,606 | 2,347,587 |
kWh
|
$0.32 |
| Electricity Demand | $79,976 | 6,350 |
kW-mo/yr
|
$12.59 |
| TOTAL YEARLY COSTS | $819,582 | |||
| RECOMMENDED SAVINGS* | $521,896 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $228 | $81 |
$208
661
kWh
|
$20
-
kW-mo/yr
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,694 | - |
$4,455
14,144
kWh
|
$239
-
kW-mo/yr
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $914 | $2,155 |
$914
2,901
kWh
|
- | - | |
| 04 | 2.2441: Preheat boiler makeup water with waste process heat | $29,218 | $8,641 |
$29,218
92,757
kWh
|
- | - | |
| 05 | 2.3142: User battery storage for power quality issues | $252,404 | $694,340 | - | - | $252,404 | |
| 06 | 2.9114: Use solar heat to make electricty | $212,681 | $1,044,647 |
$208,589
662,188
kWh
|
$4,092
-
kW-mo/yr
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,161 | $65,038 |
$17,224
54,680
kWh
|
$937
-
kW-mo/yr
|
- | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,009 | $2,699 |
$2,854
9,061
kWh
|
$155
-
kW-mo/yr
|
- | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $587 | $100 |
$557
1,768
kWh
|
$30
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $521,896 | $1,817,701 |
$264,019
838,160
kWh
|
$5,473
-
kW-mo/yr
|
$252,404 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs