Assessment Year 2025
Principal Product Plastic Bottles
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 54
Plant Area 244,135
ft2
Annual Production 198,976,257
units
Production Hrs. Annual 8,760
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $768,129 15,482,800
kWh
Electricity Demand $690,384 33,357
kW-mo/yr
Electricity Fees $8,952 -
Natural Gas $34,021 3,913
MMBtu
TOTAL YEARLY COSTS $1,501,486
RECOMMENDED SAVINGS* $173,639 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $98,157 $9,554 $62,464
1,259,361
kWh
$35,693
-
kW-mo/yr
-
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $34,835 $7,124 $22,168
446,929
kWh
$12,667
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $27,731 - $17,647
355,792
kWh
$10,084
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,367 - $2,143
43,203
kWh
$1,224
-
kW-mo/yr
-
05 2.4239: Eliminate or reduce compressed air usage $2,102 $4,200 $2,102
42,376
kWh
- -
06 2.4239: Eliminate or reduce compressed air usage $157 - $157
3,157
kWh
- -
07 2.3212: Optimize plant power factor $7,290 $15,550 - - $7,290
TOTAL RECOMMENDED $173,639 $36,428 $106,681
2,150,818
kWh
$59,668
-
kW-mo/yr
$7,290
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings