Assessment Year | 2018 |
---|---|
Principal Product | glass beads |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 27 |
Plant Area |
70,000
ft2
|
Annual Production | 46,000,000
lb
|
Production Hrs. Annual | 8,160
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,725 | 1,451,324 |
kWh
|
$0.047 |
Electricity Demand | $23,459 | 2,687 |
kW-mo/yr
|
$8.73 |
Electricity Fees | $1,400 | - |
|
- |
Natural Gas | $1,339,991 | 421,645 |
MMBtu
|
$3.18 |
TOTAL YEARLY COSTS | $1,433,575 | |||
RECOMMENDED SAVINGS* | $78,769 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $76,939 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2421: Install waste heat boiler to provide direct power | $63,539 | $195,000 |
$50,123
1,060,800
kWh
|
$13,416
-
kW-mo/yr
|
|
02 | 2.3212: Optimize plant power factor | $7,740 | $11,520 | - |
$7,740
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,670 | $1,000 |
$2,890
61,580
kWh
|
$780
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,555 | $3,232 |
$1,066
22,554
kWh
|
$489
-
kW-mo/yr
|
|
05 | 2.4239: Eliminate or reduce compressed air usage | $1,270 | $350 |
$1,270
27,220
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $560 | - |
$335
7,122
kWh
|
$225
-
kW-mo/yr
|
|
07 | 2.4314: Use synthetic lubricant | $312 | - |
$240
5,117
kWh
|
$72
-
kW-mo/yr
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $123 | $9 |
$71
1,510
kWh
|
$52
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $78,769 | $211,111 |
$55,995
1,185,903
kWh
|
$22,774
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $76,939 | $210,761 |
$54,390
1,151,561
kWh
|
$22,549
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs