Assessment Year | 2024 |
---|---|
Principal Product | Wholesale fresh fish |
NAICS | 311710: Seafood Product Preparation and Packaging |
SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
Sales Range | $50 M to 100M |
# of Employees | 75 |
Plant Area |
28,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Hawaii |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $661,707 | 2,036,588 |
kWh
|
$0.32 |
Electricity Demand | $81,234 | 5,954 |
kW-mo/yr
|
$13.64 |
TOTAL YEARLY COSTS | $742,941 | |||
RECOMMENDED SAVINGS* | $129,152 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $89,704 | $333,155 |
$87,521
269,296
kWh
|
$2,183
-
kW-mo/yr
|
|
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $32,211 | $22,296 |
$32,211
99,111
kWh
|
- | |
03 | 2.6218: Turn off equipment when not in use | $3,400 | - |
$3,400
10,460
kWh
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,837 | $1,550 |
$3,793
11,670
kWh
|
$44
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $129,152 | $357,001 |
$126,925
390,537
kWh
|
$2,227
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs