Assessment Year | 2024 |
---|---|
Principal Product | metal powder coating |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 67 |
Plant Area |
70,000
ft2
|
Annual Production | 1,000
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $261,075 | 974,895 |
kWh
|
$0.27 |
Natural Gas | $268,792 | 15,161 |
MMBtu
|
$17.73 |
TOTAL YEARLY COSTS | $529,867 | |||
RECOMMENDED SAVINGS* | $280,719 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,389 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $37,495 | $51,522 |
$37,495
139,908
kWh
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $27,700 | $28,158 |
$27,700
103,437
kWh
|
- | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $787 | $622 |
$787
2,938
kWh
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $4,268 | $3,475 | - | - |
$4,268
-
MMBtu
|
|
05 | 2.6231: Utilize controls to operate equipment only when needed | $1,528 | $468 |
$1,528
5,707
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $13 | $71 |
$13
48
kWh
|
- | - | |
07 | 2.3132: Recharge batteries on during off-peak demand periods | $1,389 | - | - | $1,389 | - | |
08 | 2.9114: Use solar heat to make electricty | $207,539 | $726,190 |
$207,539
774,981
kWh
|
- | - | |
TOTAL RECOMMENDED | $280,719 | $810,506 |
$275,062
1,027,019
kWh
|
$1,389 |
$4,268
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,389 | - | - | $1,389 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs