Assessment Year | 2025 |
---|---|
Principal Product | Tempered Glass |
NAICS | 327211: Flat Glass Manufacturing |
SIC | 3211: Flat Glass |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
100,000
ft2
|
Annual Production | 13,200,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,189,189 | 7,881,360 |
kWh
|
$0.15 |
Electricity Demand | $1,452,723 | 25,898 |
kW-mo/yr
|
$56.09 |
Natural Gas | $1,097 | 45 |
MMBtu
|
$24.54 |
TOTAL YEARLY COSTS | $2,643,009 | |||
RECOMMENDED SAVINGS* | $128,627 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,190 | - |
$7,150
47,380
kWh
|
- | - | $(-960.0) | - | |
02 | 2.6218: Turn off equipment when not in use | $11,091 | - |
$6,467
42,855
kWh
|
$4,624
-
kW-mo/yr
|
- | - | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $25,314 | $6,300 |
$25,314
167,753
kWh
|
- | - | - | - | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $55,964 | $17,866 |
$55,964
370,871
kWh
|
- | - | - | - | |
05 | 2.3132: Recharge batteries on during off-peak demand periods | $3,706 | $2,070 | - | - | $3,706 | - | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,362 | $8,453 |
$5,458
36,172
kWh
|
$3,904
-
kW-mo/yr
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,856 | $6,881 |
$6,856
45,492
kWh
|
- | - | - | - | |
08 | 2.2447: Heat water with exhaust heat | $9,559 | $18,756 |
$5,588
37,032
kWh
|
$3,971
-
kW-mo/yr
|
- | - | - | |
09 | 2.7134: Use photocell controls | $585 | $1,248 |
$509
3,374
kWh
|
- | - | $24 | $52 | |
TOTAL RECOMMENDED | $128,627 | $61,574 |
$113,306
750,929
kWh
|
$12,499
-
kW-mo/yr
|
$3,706 | $(-936.0) | $52 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs