Assessment Year 2024
Principal Product Coated metal sheets
NAICS 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 57
Plant Area 144,000
ft2
Annual Production 55,000
ton
Production Hrs. Annual 6,912
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $583,608 3,347,181
kWh
Electricity Demand $298,964 6,744
kW-mo/yr
Electricity Fees $14,410 -
Natural Gas $1,398,820 132,264
MMBtu
TOTAL YEARLY COSTS $2,295,802
RECOMMENDED SAVINGS* $1,332,876 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $16,186 - $17,086
97,970
kWh
- - $(-900.0)
02 2.4235: Remove or close off unneeded compressed air lines $6,885 $3,504 $6,885
39,481
kWh
- - -
03 2.2443: Re-use or recycle hot or cold process exhaust air $99,094 $49,118 - - $99,094
-
MMBtu
-
04 2.2442: Preheat combustion air with waste heat $614,286 $1,532,000 - - $614,286
-
MMBtu
-
05 2.4226: Use / purchase optimum sized compressor $44,171 $125,600 $30,074
172,440
kWh
$14,097
-
kW-mo/yr
- -
06 2.9114: Use solar heat to make electricty $552,254 $2,633,668 $552,254
3,166,592
kWh
- - -
TOTAL RECOMMENDED $1,332,876 $4,343,890 $606,299
3,476,483
kWh
$14,097
-
kW-mo/yr
$713,380
-
MMBtu
$(-900.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs