Assessment Year | 2024 |
---|---|
Principal Product | Almonds |
NAICS | 311911: Roasted Nuts and Peanut Butter Manufacturing |
SIC | 2068: Salted and Roasted Nuts and Seeds |
Sales Range | greater than $500 M |
# of Employees | 250 |
Plant Area |
252,000
ft2
|
Annual Production | 438,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,407,697 | 14,445,517 |
kWh
|
$0.097 |
Electricity Demand | $379,609 | 34,187 |
kW-mo/yr
|
$11.10 |
Natural Gas | $1,229,723 | 126,184 |
MMBtu
|
$9.75 |
TOTAL YEARLY COSTS | $3,017,029 | |||
RECOMMENDED SAVINGS* | $262,301 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $247,039 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $14,817 | - |
$14,817
152,129
kWh
|
- | |
02 | 2.6218: Turn off equipment when not in use | $4,908 | - |
$4,908
50,394
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $61,975 | $1,800 |
$61,975
639,299
kWh
|
- | |
04 | 2.4239: Eliminate or reduce compressed air usage | $6,353 | $2,100 |
$6,353
65,229
kWh
|
- | |
05 | 2.2441: Preheat boiler makeup water with waste process heat | $8,909 | $18,675 | - |
$8,909
-
MMBtu
|
|
06 | 2.9114: Use solar heat to make electricty | $165,339 | $1,651,070 |
$165,339
1,697,522
kWh
|
- | |
TOTAL RECOMMENDED | $262,301 | $1,673,645 |
$253,392
2,604,573
kWh
|
$8,909
-
MMBtu
|
||
TOTAL IMPLEMENTED | $247,039 | $1,652,870 |
$247,039
2,539,344
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs