Assessment Year | 2023 |
---|---|
Principal Product | Audio Speakers |
NAICS | 334310: Audio and Video Equipment Manufacturing |
SIC | 3651: Household Audio and Video Equipment |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
49,000
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 2,384
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $385,087 | 1,447,554 |
kWh
|
$0.27 |
Electricity Demand | $24,590 | 2,757 |
kW-mo/yr
|
$8.92 |
Electricity Fees | $29,401 | - |
|
- |
Natural Gas | $108,181 | 4,609 |
MMBtu
|
$23.47 |
TOTAL YEARLY COSTS | $547,259 | |||
RECOMMENDED SAVINGS* | $208,590 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,294 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $24,945 | $4,958 |
$14,925
52,132
kWh
|
- |
$10,020
-
MMBtu
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $848 | $420 |
$733
2,561
kWh
|
$115
-
kW-mo/yr
|
- | - | - | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $28,696 | $38,888 |
$28,696
100,231
kWh
|
- | - | - | - | |
04 | 2.7135: Install occupancy sensors | $2,116 | $10,832 |
$1,975
6,897
kWh
|
- | - | $102 | $39 | |
05 | 2.2511: Insulate bare equipment | $233 | $1,287 |
$233
814
kWh
|
- | - | - | - | |
06 | 3.6192: Use a less expensive method of waste removal | $21,756 | $37,440 | - | - | - | $21,756 | - | |
07 | 2.9114: Use solar heat to make electricty | $129,996 | $428,510 |
$129,996
454,056
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $208,590 | $522,335 |
$176,558
616,691
kWh
|
$115
-
kW-mo/yr
|
$10,020
-
MMBtu
|
$21,858 | $39 | ||
TOTAL IMPLEMENTED | $27,294 | $17,077 |
$17,133
59,843
kWh
|
- |
$10,020
-
MMBtu
|
$102 | $39 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs