| Assessment Year | 2022 |
|---|---|
| Principal Product | Semi Conductor Photomask |
| NAICS | 334413: Semiconductor and Related Device Manufacturing |
| SIC | 3674: Semiconductors and Related Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 35 |
| Plant Area |
36,000
ft2
|
| Annual Production | 18,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $547,815 | 4,867,963 |
kWh
|
$0.11 |
| Electricity Demand | $268,264 | 7,844 |
kW-mo/yr
|
$34.20 |
| Electricity Fees | $5,706 | - |
|
- |
| Natural Gas | $10,393 | 646 |
MMBtu
|
$16.09 |
| TOTAL YEARLY COSTS | $832,178 | |||
| RECOMMENDED SAVINGS* | $152,636 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,279 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $1,341 | - |
$1,341
8,332
kWh
|
- | - | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $10,174 | $2,893 |
$1,477
9,175
kWh
|
- |
$8,697
-
MMBtu
|
- | |
| 03 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $23,840 | $8,000 |
$23,840
148,072
kWh
|
- | - | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $897 | $400 |
$656
4,075
kWh
|
$241
-
kW-mo/yr
|
- | - | |
| 05 | 2.4151: Develop a repair/replace policy | $3,867 | $8,345 |
$2,842
17,651
kWh
|
$1,025
-
kW-mo/yr
|
- | - | |
| 06 | 2.9114: Use solar heat to make electricty | $95,415 | $561,099 |
$95,415
592,641
kWh
|
- | - | - | |
| 07 | 3.1191: Change procedures / equipment / operating conditions | $17,102 | $105,401 | - | - | - | $17,102 | |
| TOTAL RECOMMENDED | $152,636 | $686,138 |
$125,571
779,946
kWh
|
$1,266
-
kW-mo/yr
|
$8,697
-
MMBtu
|
$17,102 | ||
| TOTAL IMPLEMENTED | $16,279 | $11,638 |
$6,316
39,233
kWh
|
$1,266
-
kW-mo/yr
|
$8,697
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs