Assessment Year 2022
Principal Product Bottled Red and White Wines
NAICS 312130: Wineries
SIC 2084: Wines, Brandy, and Brandy Spirits
Sales Range $100
M
to 500
M
# of Employees 100
Plant Area 500,000
ft2
Annual Production 4,756
Tgal
Production Hrs. Annual 4,552
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $490,095 4,215,345
kWh
Electricity Demand $195,120 7,560
kW-mo/yr
Electricity Fees $24,005 -
Natural Gas $104,053 9,457
MMBtu
Waste Disposal Costs
Water Usage $37,480 16,284
Tgal
TOTAL YEARLY COSTS $850,753
RECOMMENDED SAVINGS* $135,318 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $53,315

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.2694: Use highest temperature for chilling or cold storage $18,446 - $18,446
127,304
kWh
- - -
02 2.7224: Reduce space conditioning during non-working hours $12,288 $1,410 $3,031
20,920
kWh
- - $9,257
-
MMBtu
03 2.2621: Modify refrigeration system to operate at a lower pressure $69,715 $64,882 $69,715
481,126
kWh
- - -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $13,463 $18,200 $13,463
92,913
kWh
- - -
05 2.3132: Recharge batteries on during off-peak demand periods $1,242 $2,702 - - $1,242 -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $228 $574 $184
1,266
kWh
$44
-
kW-mo/yr
- -
07 2.6231: Utilize controls to operate equipment only when needed $19,936 $49,917 $16,026
110,600
kWh
$3,910
-
kW-mo/yr
- -
TOTAL RECOMMENDED $135,318 $137,685 $120,865
834,129
kWh
$3,954
-
kW-mo/yr
$1,242 $9,257
-
MMBtu
TOTAL IMPLEMENTED $53,315 $71,393 $48,119
332,083
kWh
$3,954
-
kW-mo/yr
$1,242 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs