Assessment Year | 2022 |
---|---|
Principal Product | Bottled Red and White Wines |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $100 M to 500M |
# of Employees | 100 |
Plant Area |
500,000
ft2
|
Annual Production | 4,756
Tgal
|
Production Hrs. Annual | 4,552
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $490,095 | 4,215,345 |
kWh
|
$0.12 | |
Electricity Demand | $195,120 | 7,560 |
kW-mo/yr
|
$25.81 | |
Electricity Fees | $24,005 | - |
|
- | |
Natural Gas | $104,053 | 9,457 |
MMBtu
|
$11.00 | |
Waste Disposal Costs | |||||
Water Usage | $37,480 | 16,284 |
Tgal
|
$2.30 | |
TOTAL YEARLY COSTS | $850,753 | ||||
RECOMMENDED SAVINGS* | $135,318 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $53,315 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2694: Use highest temperature for chilling or cold storage | $18,446 | - |
$18,446
127,304
kWh
|
- | - | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $12,288 | $1,410 |
$3,031
20,920
kWh
|
- | - |
$9,257
-
MMBtu
|
|
03 | 2.2621: Modify refrigeration system to operate at a lower pressure | $69,715 | $64,882 |
$69,715
481,126
kWh
|
- | - | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,463 | $18,200 |
$13,463
92,913
kWh
|
- | - | - | |
05 | 2.3132: Recharge batteries on during off-peak demand periods | $1,242 | $2,702 | - | - | $1,242 | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $228 | $574 |
$184
1,266
kWh
|
$44
-
kW-mo/yr
|
- | - | |
07 | 2.6231: Utilize controls to operate equipment only when needed | $19,936 | $49,917 |
$16,026
110,600
kWh
|
$3,910
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $135,318 | $137,685 |
$120,865
834,129
kWh
|
$3,954
-
kW-mo/yr
|
$1,242 |
$9,257
-
MMBtu
|
||
TOTAL IMPLEMENTED | $53,315 | $71,393 |
$48,119
332,083
kWh
|
$3,954
-
kW-mo/yr
|
$1,242 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs