Assessment Year | 2002 |
---|---|
Principal Product | precooked meat products |
NAICS |
n/a
|
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $100 M to 500M |
# of Employees | 374 |
Plant Area |
180,000
ft2
|
Annual Production | 7,332,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $521,569 | 19,323,480 |
kWh
|
$0.027 |
Electricity Demand | $150,560 | 33,140 |
kW-mo/yr
|
$4.54 |
Natural Gas | $545,562 | 112,640 |
MMBtu
|
$4.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,510 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,396 | $581 |
$1,012
50,110
kWh
|
$384
-
kW-mo/yr
|
- | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $999 | $241 |
$725
35,871
kWh
|
$274
-
kW-mo/yr
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $418 | $16 |
$303
14,976
kWh
|
$115
-
kW-mo/yr
|
- | - | - | |
04 | 3.4156: Use flow control valves on equipment to optimize water use | $1,463 | - | - | - |
$307
-
MMBtu
|
$875
-
Tgal
|
$281
-
Tgal
|
|
05 | 2.4133: Use most efficient type of electric motors | $12,482 | - |
$9,400
465,346
kWh
|
$3,082
-
kW-mo/yr
|
- | - | - | |
06 | 2.7135: Install occupancy sensors | $1,464 | $1,663 |
$1,464
72,481
kWh
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,844 | $13,381 |
$2,158
106,856
kWh
|
$686
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,670 | - |
$2,027
100,339
kWh
|
$643
-
kW-mo/yr
|
- | - | - | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,312 | $1,500 | - | - |
$1,312
-
MMBtu
|
- | - | |
10 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,212 | $1,500 | - | - |
$2,212
-
MMBtu
|
- | - | |
11 | 2.1213: Direct warmest air to combustion intake | $1,752 | $500 | - | - |
$1,752
-
MMBtu
|
- | - | |
12 | 2.2136: Install / repair insulation on steam lines | $843 | $326 | - | - |
$843
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $29,855 | $19,708 |
$17,089
845,979
kWh
|
$5,184
-
kW-mo/yr
|
$6,426
-
MMBtu
|
$875
-
Tgal
|
$281
-
Tgal
|
||
TOTAL IMPLEMENTED | $26,510 | $18,029 |
$15,322
758,522
kWh
|
$5,069
-
kW-mo/yr
|
$6,119
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs