Assessment Year 2021
Principal Product Still Wines
NAICS 312130: Wineries
SIC 2084: Wines, Brandy, and Brandy Spirits
Sales Range greater than $500
M
# of Employees 160
Plant Area 510,000
ft2
Annual Production 12,800
Tgal
Production Hrs. Annual 4,160
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,323,479 9,946,685
kWh
Electricity Demand $197,497 9,996
kW-mo/yr
Natural Gas $145,807 13,277
MMBtu
Waste Disposal Costs
Water Disposal $66,116 8,388
Tgal
TOTAL YEARLY COSTS $1,732,899
RECOMMENDED SAVINGS* $611,471 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $456,455

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $24,674 - $24,674
133,302
kWh
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $27,893 - $27,893
157,176
kWh
- - -
03 2.2691: Shut off cooling if cold outside air will cool process $149,399 $10,195 $149,399
807,124
kWh
- - -
04 2.7224: Reduce space conditioning during non-working hours $71,549 $5,641 $38,815
209,697
kWh
- $32,734
-
MMBtu
-
05 2.2621: Modify refrigeration system to operate at a lower pressure $106,544 $31,500 $106,544
575,606
kWh
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $514 $190 $448
2,422
kWh
$66
-
kW-mo/yr
- -
07 2.6231: Utilize controls to operate equipment only when needed $39,174 $48,150 $39,174
211,636
kWh
- - -
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,387 $6,315 $3,387
18,400
kWh
- - -
09 2.4239: Eliminate or reduce compressed air usage $291 $648 $291
1,571
kWh
- - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $8,784 $27,535 $5,546
29,962
kWh
$1,305
-
kW-mo/yr
- $1,933
11 2.9114: Use solar heat to make electricty $179,262 $1,269,472 $175,657
1,612,267
kWh
$3,605
-
kW-mo/yr
- -
TOTAL RECOMMENDED $611,471 $1,399,646 $571,828
3,759,163
kWh
$4,976
-
kW-mo/yr
$32,734
-
MMBtu
$1,933
TOTAL IMPLEMENTED $456,455 $1,292,271 $420,116
2,939,537
kWh
$3,605
-
kW-mo/yr
$32,734
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs