Assessment Year | 2021 |
---|---|
Principal Product | Still Wines |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | greater than $500 M |
# of Employees | 160 |
Plant Area |
510,000
ft2
|
Annual Production | 12,800
Tgal
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,323,479 | 9,946,685 |
kWh
|
$0.13 | |
Electricity Demand | $197,497 | 9,996 |
kW-mo/yr
|
$19.76 | |
Natural Gas | $145,807 | 13,277 |
MMBtu
|
$10.98 | |
Waste Disposal Costs | |||||
Water Disposal | $66,116 | 8,388 |
Tgal
|
$7.88 | |
TOTAL YEARLY COSTS | $1,732,899 | ||||
RECOMMENDED SAVINGS* | $611,471 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $456,455 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $24,674 | - |
$24,674
133,302
kWh
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $27,893 | - |
$27,893
157,176
kWh
|
- | - | - | |
03 | 2.2691: Shut off cooling if cold outside air will cool process | $149,399 | $10,195 |
$149,399
807,124
kWh
|
- | - | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $71,549 | $5,641 |
$38,815
209,697
kWh
|
- |
$32,734
-
MMBtu
|
- | |
05 | 2.2621: Modify refrigeration system to operate at a lower pressure | $106,544 | $31,500 |
$106,544
575,606
kWh
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $514 | $190 |
$448
2,422
kWh
|
$66
-
kW-mo/yr
|
- | - | |
07 | 2.6231: Utilize controls to operate equipment only when needed | $39,174 | $48,150 |
$39,174
211,636
kWh
|
- | - | - | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,387 | $6,315 |
$3,387
18,400
kWh
|
- | - | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $291 | $648 |
$291
1,571
kWh
|
- | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,784 | $27,535 |
$5,546
29,962
kWh
|
$1,305
-
kW-mo/yr
|
- | $1,933 | |
11 | 2.9114: Use solar heat to make electricty | $179,262 | $1,269,472 |
$175,657
1,612,267
kWh
|
$3,605
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $611,471 | $1,399,646 |
$571,828
3,759,163
kWh
|
$4,976
-
kW-mo/yr
|
$32,734
-
MMBtu
|
$1,933 | ||
TOTAL IMPLEMENTED | $456,455 | $1,292,271 |
$420,116
2,939,537
kWh
|
$3,605
-
kW-mo/yr
|
$32,734
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs