Assessment Year 2020
Principal Product Frozen Bell Peppers
NAICS 311411: Frozen Fruit, Juice, and Vegetable Manufacturing
SIC 2037: Frozen Fruits, Fruit Juices, and Vegetables
Sales Range $50
M
to 100
M
# of Employees 250
Plant Area 150,000
ft2
Annual Production 90,000,000
lb
Production Hrs. Annual 1,792
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $601,230 8,157,700
kWh
Electricity Demand $340,736 19,164
kW-mo/yr
Natural Gas $109,671 14,329
MMBtu
TOTAL YEARLY COSTS $1,051,637
RECOMMENDED SAVINGS* $43,420 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,380

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $427 $80 $310
4,201
kWh
$117
-
kW-mo/yr
- - -
02 2.2192: Use heat exchange fluids instead of steam in pipeline tracing systems $21,879 $20,311 - - $21,879
-
MMBtu
- -
03 2.2511: Insulate bare equipment $386 $404 - - $386
-
MMBtu
- -
04 2.7447: Install vinyl strip / high speed / air curtain doors $4,802 $5,638 $4,802
65,149
kWh
- - - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $10,099 $13,511 $6,538
88,710
kWh
$3,219
-
kW-mo/yr
- $260 $82
06 2.2511: Insulate bare equipment $1,140 $1,577 - - $1,140
-
MMBtu
- -
07 2.3132: Recharge batteries on during off-peak demand periods $871 $1,184 - $871
-
kW-mo/yr
- - -
08 2.4231: Reduce the pressure of compressed air to the minimum required $833 $1,245 $833
11,303
kWh
- - - -
09 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $632 $1,312 $411
5,573
kWh
$221
-
kW-mo/yr
- - -
10 2.7447: Install vinyl strip / high speed / air curtain doors $2,351 $5,888 $2,351
31,894
kWh
- - - -
TOTAL RECOMMENDED $43,420 $51,150 $15,245
206,830
kWh
$4,428
-
kW-mo/yr
$23,405
-
MMBtu
$260 $82
TOTAL IMPLEMENTED $14,380 $21,975 $9,610
130,378
kWh
$4,428
-
kW-mo/yr
- $260 $82
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs