Assessment Year 2016
Principal Product Wine
NAICS 312130: Wineries
SIC 2084: Wines, Brandy, and Brandy Spirits
Sales Range $100
M
to 500
M
# of Employees 9
Plant Area 491,825
ft2
Annual Production 9,000
units
Production Hrs. Annual 6,240
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $92,404 1,273,878
kWh
Electricity Demand $211,582 7,229
kW-mo/yr
TOTAL YEARLY COSTS $303,986
RECOMMENDED SAVINGS* $38,638 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,527

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.6218: Turn off equipment when not in use $1,773 - $905
12,480
kWh
$868
-
kW-mo/yr
-
02 2.4226: Use / purchase optimum sized compressor $4,441 $2,520 $4,441
61,262
kWh
- -
03 2.2621: Modify refrigeration system to operate at a lower pressure $9,855 $16,147 $9,855
135,854
kWh
- -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,458 $15,229 $5,853
80,683
kWh
$2,605
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $13,391 $47,502 $8,127
112,030
kWh
$4,228
-
kW-mo/yr
$1,036
06 2.2444: Use hot process fluids to preheat incoming process fluids $720 $4,000 $720
9,936
kWh
- -
TOTAL RECOMMENDED $38,638 $85,398 $29,901
412,245
kWh
$7,701
-
kW-mo/yr
$1,036
TOTAL IMPLEMENTED $24,527 $33,896 $21,054
290,279
kWh
$3,473
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs