ITAC Assessment: SF0482
ITAC logo
ITAC Assessment: SF0482
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Wine
NAICS 312130: Wineries
SIC 2084: Wines, Brandy, and Brandy Spirits
Sales Range $100
M
to 500
M
# of Employees 24
Plant Area 826,595
ft2
Annual Production 28,000
Tgal
Production Hrs. Annual 6,240
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $206,022 1,998,820
kWh
Electricity Demand $189,473 6,307
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $60,213 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $29,396

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7224: Reduce space conditioning during non-working hours $5,467 - $5,467
53,038
kWh
-
02 2.2694: Use highest temperature for chilling or cold storage $4,678 - $2,998
29,084
kWh
$1,680
-
kW-mo/yr
03 2.2621: Modify refrigeration system to operate at a lower pressure $19,190 $13,256 $19,190
186,188
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $21,464 $27,738 $13,472
130,703
kWh
$7,992
-
kW-mo/yr
05 2.2444: Use hot process fluids to preheat incoming process fluids $1,989 $4,000 $1,989
19,299
kWh
-
06 2.6231: Utilize controls to operate equipment only when needed $2,686 $8,251 $2,686
26,066
kWh
-
07 2.7135: Install occupancy sensors $4,739 $14,109 $2,488
24,137
kWh
$2,251
-
kW-mo/yr
TOTAL RECOMMENDED $60,213 $67,354 $48,290
468,515
kWh
$11,923
-
kW-mo/yr
TOTAL IMPLEMENTED $29,396 $27,365 $27,145
263,363
kWh
$2,251
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs