Assessment Year | 2016 |
---|---|
Principal Product | Processed almonds |
NAICS | 115114: Postharvest Crop Activities (except Cotton Ginning) |
SIC | 0723: Crop Preparation Services for Market, Except Cotton Ginning |
Sales Range | $100 M to 500M |
# of Employees | 100 |
Plant Area |
85,000
ft2
|
Annual Production | 20,000,000
lb
|
Production Hrs. Annual | 4,096
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $136,273 | 1,386,317 |
kWh
|
$0.098 |
Electricity Demand | $82,728 | 5,514 |
kW-mo/yr
|
$15.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $129,754 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $111,903 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6242: Minimize operation of equipment maintained in standby condition | $2,228 | - |
$1,186
12,061
kWh
|
$1,042
-
kW-mo/yr
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $187 | - |
$187
1,905
kWh
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,403 | $354 |
$3,734
37,985
kWh
|
$1,669
-
kW-mo/yr
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,097 | $219 |
$867
8,819
kWh
|
$230
-
kW-mo/yr
|
- | - | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $6,005 | $4,163 |
$6,005
61,086
kWh
|
- | - | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,322 | $10,120 |
$4,207
42,799
kWh
|
$1,115
-
kW-mo/yr
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,524 | $22,649 |
$4,281
43,546
kWh
|
$2,557
-
kW-mo/yr
|
$282 | $(-596.0) | |
08 | 2.7135: Install occupancy sensors | $6,041 | $31,062 |
$3,425
34,845
kWh
|
$2,616
-
kW-mo/yr
|
- | - | |
09 | 2.9114: Use solar heat to make electricty | $96,947 | $904,867 |
$69,313
705,121
kWh
|
$27,634
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $129,754 | $973,434 |
$93,205
948,167
kWh
|
$36,863
-
kW-mo/yr
|
$282 | $(-596.0) | ||
TOTAL IMPLEMENTED | $111,903 | $936,502 |
$78,712
800,736
kWh
|
$33,191
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs