ITAC Assessment: SF0457
ITAC logo
ITAC Assessment: SF0457
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2014
Principal Product Speciality Chemicals
NAICS 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing
SIC 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 123
Plant Area 136,551
ft2
Annual Production 40,000,000
lb
Production Hrs. Annual 2,210
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $80,320 752,799
kWh
Electricity Demand $54,463 4,812
kW-mo/yr
Natural Gas $6,914 747
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $116,445 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,880

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Primary Raw Material Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,158 $180 $1,011
9,475
kWh
$147
-
kW-mo/yr
- -
02 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,323 - - $2,323
-
kW-mo/yr
- -
03 2.3131: Reschedule plant operations or reduce load to avoid peaks $10,640 $4,356 - $10,640
-
kW-mo/yr
- -
04 2.7135: Install occupancy sensors $4,973 $3,386 $3,194
29,940
kWh
$1,779
-
kW-mo/yr
- -
05 2.4221: Install compressor air intakes in coolest locations $487 $898 $339
3,175
kWh
$148
-
kW-mo/yr
- -
06 2.6211: Conserve energy by efficient use of vending machines $270 $597 $270
2,529
kWh
- - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $5,420 $21,352 $4,636
43,452
kWh
$489
-
kW-mo/yr
$223 $72
08 2.9114: Use solar heat to make electricty $91,174 $463,974 $79,615
746,230
kWh
$11,559
-
kW-mo/yr
- -
TOTAL RECOMMENDED $116,445 $494,743 $89,065
834,801
kWh
$27,085
-
kW-mo/yr
$223 $72
TOTAL IMPLEMENTED $10,880 $25,636 $8,169
76,567
kWh
$2,416
-
kW-mo/yr
$223 $72
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Primary Raw Material Savings