Assessment Year | 2013 |
---|---|
Principal Product | Cereal Varieties |
NAICS | 311230: Breakfast Cereal Manufacturing |
SIC | 2043: Cereal Breakfast Foods |
Sales Range | $10 M to 50M |
# of Employees | 145 |
Plant Area |
1,100,000
ft2
|
Annual Production | 54,000,000
lb
|
Production Hrs. Annual | 5,400
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $792,750 | 13,637,718 |
kWh
|
$0.058 |
Electricity Demand | $422,745 | 33,972 |
kW-mo/yr
|
$12.44 |
Natural Gas | $584,431 | 143,286 |
MMBtu
|
$4.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $121,479 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,811 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $7,313 | - |
$7,313
124,799
kWh
|
- | - | - | - | - | |
02 | 2.7311: Ventilation system to shut off when room is not in use | $5,121 | - |
$3,968
67,711
kWh
|
$1,153
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.2121: Increase amount of condensate returned | $13,990 | $3,780 | - | - | - |
$10,081
-
MMBtu
|
- |
$3,909
-
gal
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $4,736 | $1,751 |
$3,311
56,509
kWh
|
$1,425
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.2511: Insulate bare equipment | $584 | $329 | - | - | - |
$584
-
MMBtu
|
- | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $26,782 | $19,063 |
$16,877
288,000
kWh
|
$14,916
-
kW-mo/yr
|
- |
$(-5,011.0)
-
MMBtu
|
- | - | |
07 | 2.2511: Insulate bare equipment | $1,669 | $1,332 | - | - | - | - |
$1,669
-
MMBtu
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $542 | $421 |
$343
5,853
kWh
|
$199
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,709 | $11,701 |
$12,709
216,884
kWh
|
- | - | - | - | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,972 | $12,679 |
$10,988
187,511
kWh
|
$984
-
kW-mo/yr
|
- | - | - | - | |
11 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,652 | $9,933 |
$7,700
131,399
kWh
|
$2,238
-
kW-mo/yr
|
- |
$(-2,286.0)
-
MMBtu
|
- | - | |
12 | 2.7135: Install occupancy sensors | $15,352 | $26,883 |
$9,851
168,100
kWh
|
$5,501
-
kW-mo/yr
|
- | - | - | - | |
13 | 2.2522: Isolate hot or cold equipment | $2,222 | $6,975 | - | - | - |
$2,222
-
MMBtu
|
- | - | |
14 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,775 | $25,138 |
$6,134
104,681
kWh
|
$1,326
-
kW-mo/yr
|
- |
$(-1,685.0)
-
MMBtu
|
- | - | |
15 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,060 | $57,544 |
$3,697
63,081
kWh
|
$1,047
-
kW-mo/yr
|
$316 | - | - | - | |
TOTAL RECOMMENDED | $121,479 | $177,529 |
$82,891
1,414,528
kWh
|
$28,789
-
kW-mo/yr
|
$316 |
$3,905
-
MMBtu
|
$1,669
-
MMBtu
|
$3,909
-
gal
|
||
TOTAL IMPLEMENTED | $30,811 | $15,762 |
$25,580
436,530
kWh
|
$3,562
-
kW-mo/yr
|
- | - |
$1,669
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Other Liquid (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs