Assessment Year | 2012 |
---|---|
Principal Product | Cheese and Whey Products |
NAICS | 311513: Cheese Manufacturing |
SIC | 2022: Natural, Processed, and Imitation Cheese |
Sales Range | $50 M to 100M |
# of Employees | 98 |
Plant Area |
53,000
ft2
|
Annual Production | 52,000,000
lb
|
Production Hrs. Annual | 8,616
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $676,678 | 9,244,000 |
kWh
|
$0.073 |
Electricity Demand | $159,091 | 15,700 |
kW-mo/yr
|
$10.13 |
Electricity Fees | $15,161 | - |
|
- |
Natural Gas | $361,866 | 60,988 |
MMBtu
|
$5.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $71,870 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,554 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2621: Modify refrigeration system to operate at a lower pressure | $44,715 | - |
$37,718
504,255
kWh
|
$6,997
-
kW-mo/yr
|
- | - | - | |
02 | 2.2135: Repair and eliminate steam leaks | $7,965 | $672 | - | - |
$7,965
-
MMBtu
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,152 | $672 |
$5,152
68,876
kWh
|
- | - | - | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $3,004 | - |
$640
8,559
kWh
|
- |
$2,364
-
MMBtu
|
- | - | |
05 | 2.7292: Lower ceiling to reduce conditioned space | $1,231 | $630 |
$1,231
16,454
kWh
|
- | - | - | - | |
06 | 2.2136: Install / repair insulation on steam lines | $1,437 | $1,299 | - | - |
$1,437
-
MMBtu
|
- | - | |
07 | 2.7132: Install timers on light switches in little used areas | $326 | $312 |
$283
3,796
kWh
|
$43
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,040 | $28,647 |
$4,548
60,808
kWh
|
$704
-
kW-mo/yr
|
- | $1,506 | $1,282 | |
TOTAL RECOMMENDED | $71,870 | $32,232 |
$49,572
662,748
kWh
|
$7,744
-
kW-mo/yr
|
$11,766
-
MMBtu
|
$1,506 | $1,282 | ||
TOTAL IMPLEMENTED | $14,554 | $2,643 |
$5,152
68,876
kWh
|
- |
$9,402
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs