Assessment Year | 2010 |
---|---|
Principal Product | Lawn Edging from Recycled Plastics |
NAICS | 333112: Lawn and Garden Tractor and Home Lawn and Garden Equipment Manufacturing |
SIC | 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment |
Sales Range | $5 M to 10M |
# of Employees | 25 |
Plant Area |
139,392
ft2
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $350,481 | 2,814,709 |
kWh
|
$0.12 |
Electricity Demand | $52,188 | 11,244 |
kW-mo/yr
|
$4.64 |
Electricity Fees | $6,520 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $58,422 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,240 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2211: Use optimum temperature | $2,152 | - |
$2,152
17,282
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,764 | $7,740 |
$13,764
110,539
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $4,908 | $3,317 |
$4,908
39,416
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,745 | $23,088 |
$18,191
146,094
kWh
|
$1,554
-
kW-mo/yr
|
|
05 | 2.2511: Insulate bare equipment | $2,633 | $4,117 |
$2,226
17,877
kWh
|
$407
-
kW-mo/yr
|
|
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,502 | $6,175 |
$3,113
24,996
kWh
|
$389
-
kW-mo/yr
|
|
07 | 2.7135: Install occupancy sensors | $841 | $2,812 |
$696
5,591
kWh
|
$145
-
kW-mo/yr
|
|
08 | 2.4239: Eliminate or reduce compressed air usage | $4,109 | $14,000 |
$3,309
26,574
kWh
|
$800
-
kW-mo/yr
|
|
09 | 2.4224: Upgrade controls on compressors | $6,768 | $25,263 |
$6,768
54,355
kWh
|
- | |
TOTAL RECOMMENDED | $58,422 | $86,512 |
$55,127
442,724
kWh
|
$3,295
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $26,240 | $32,075 |
$24,152
193,963
kWh
|
$2,088
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs