Assessment Year | 2008 |
---|---|
Principal Product | Building Supply |
NAICS | 321918: Other Millwork (including Flooring) |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
54,000
ft2
|
Annual Production | 1
pieces
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | Hawaii |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $197,789 | 544,920 |
kWh
|
$0.36 |
Electricity Demand | $21,477 | 3,068 |
kW-mo/yr
|
$7.00 |
Electricity Fees | $86,177 | - |
|
- |
Other Gas | $19,513 | 944 |
MMBtu
|
$20.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,186 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,905 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,775 | - |
$10,775
37,928
kWh
|
- | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $4,455 | $452 |
$4,455
14,303
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $3,202 | $1,339 |
$2,867
9,946
kWh
|
$335
-
kW-mo/yr
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $176 | $93 |
$151
503
kWh
|
$25
-
kW-mo/yr
|
|
05 | 2.6231: Utilize controls to operate equipment only when needed | $2,839 | $2,119 |
$2,839
9,847
kWh
|
- | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $2,476 | $2,404 |
$2,476
8,587
kWh
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,134 | $4,709 |
$3,036
9,843
kWh
|
$98
-
kW-mo/yr
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $853 | $2,892 |
$853
2,958
kWh
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $276 | $953 |
$251
220
kWh
|
$25
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $28,186 | $14,961 |
$27,703
94,135
kWh
|
$483
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $16,905 | $4,789 |
$16,520
57,184
kWh
|
$385
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs