Assessment Year | 2005 |
---|---|
Principal Product | Sweetened Condensed Milk, Pancake Syrup, Olive Oil Packaging |
NAICS | 311514: Dry, Condensed, and Evaporated Dairy Product Manufacturing |
SIC | 2023: Dry, Condensed, and Evaporated Dairy Products |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
70,000
ft2
|
Annual Production | 12,500,000
lb
|
Production Hrs. Annual | 4,125
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,306 | 698,160 |
kWh
|
$0.16 |
Natural Gas | $63,335 | 7,195 |
MMBtu
|
$8.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,679 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,347 | $480 |
$2,347
19,208
kWh
|
- | - | - | |
02 | 2.2135: Repair and eliminate steam leaks | $728 | $120 | - | - |
$728
-
MMBtu
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,633 | $3,457 |
$3,155
25,841
kWh
|
$478
-
kW-mo/yr
|
- | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $4,150 | $2,900 |
$3,840
(-7,966)
kWh
|
$310
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $1,456 | $1,635 |
$1,296
10,610
kWh
|
$160
-
kW-mo/yr
|
- | - | |
06 | 2.2511: Insulate bare equipment | $1,570 | $1,687 | - | - |
$1,570
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,218 | $24,484 |
$11,987
98,175
kWh
|
$1,231
-
kW-mo/yr
|
- | - | |
08 | 2.4224: Upgrade controls on compressors | $6,777 | $18,995 |
$6,146
50,337
kWh
|
$631
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,603 | $14,240 |
$2,274
18,623
kWh
|
$329
-
kW-mo/yr
|
- | - | |
10 | 3.3123: Use decanting, flotation to remove contaminants | $38,197 | $66,900 | - | - | - |
$38,197
-
gal
|
|
TOTAL RECOMMENDED | $74,679 | $134,898 |
$31,045
214,828
kWh
|
$3,139
-
kW-mo/yr
|
$2,298
-
MMBtu
|
$38,197
-
gal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs