| Assessment Year | 2001 |
|---|---|
| Principal Product | Plastic Molding |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
83,000
ft2
|
| Annual Production | 350
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $294,544 | 2,754,626 |
kWh
|
$0.11 |
| Natural Gas | $5,373 | 507 |
MMBtu
|
$10.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $74,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,051 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $185 | - |
$185
1,521
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,977 | $480 |
$4,977
44,803
kWh
|
- | |
| 03 | 2.4224: Upgrade controls on compressors | $2,046 | $344 |
$2,046
16,801
kWh
|
- | |
| 04 | 2.2612: Use cooling tower water instead of refrigeration | $2,217 | $495 |
$2,217
18,204
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $1,099 | $840 |
$1,099
9,023
kWh
|
- | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,141 | $7,697 |
$7,141
58,632
kWh
|
- | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,570 | $2,262 |
$1,570
12,890
kWh
|
- | |
| 08 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $1,259 | $1,259 |
$1,259
50,657
kWh
|
- | |
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $53,204 | $139,820 |
$53,204
436,815
kWh
|
- | |
| 10 | 3.5217: Reuse / recycle/ sell paper products | $584 | $80 | - |
$584
-
gal
|
|
| TOTAL RECOMMENDED | $74,282 | $153,277 |
$73,698
649,346
kWh
|
$584
-
gal
|
||
| TOTAL IMPLEMENTED | $9,051 | $2,163 |
$8,467
113,782
kWh
|
$584
-
gal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Liquid (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs