Assessment Year | 2000 |
---|---|
Principal Product | Plastic Pails |
NAICS |
n/a
|
SIC | 3079: |
Sales Range | $10 M to 50M |
# of Employees | 96 |
Plant Area |
46,368
ft2
|
Annual Production | 6,000,000
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $637,523 | 11,693,269 |
kWh
|
$0.055 |
Natural Gas | $10,520 | 1,651 |
MMBtu
|
$6.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $90,893 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,979 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 3.7392: Apply a protective coating to racks and tanks | $1,878 | - |
$1,878
36,048
kWh
|
- | - | |
02 | 4.711: Initiate a total quality management program | $834 | - |
$834
19,500
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $7,130 | $977 |
$7,130
166,642
kWh
|
- | - | |
04 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $5,706 | $2,936 |
$5,706
133,358
kWh
|
- | - | |
05 | 2.7135: Install occupancy sensors | $1,053 | $600 |
$1,053
24,601
kWh
|
- | - | |
06 | 2.4133: Use most efficient type of electric motors | $3,000 | $3,333 |
$3,000
57,441
kWh
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,489 | $22,680 |
$14,489
338,641
kWh
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $233 | $228 |
$233
4,396
kWh
|
- | - | |
09 | 2.7135: Install occupancy sensors | $565 | $1,500 |
$565
13,209
kWh
|
- | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $51,408 | $178,376 |
$51,408
1,201,533
kWh
|
- | - | |
11 | 3.5217: Reuse / recycle/ sell paper products | $1,800 | - | - |
$1,800
-
lb
|
- | |
12 | 2.3212: Optimize plant power factor | $2,797 | $6,436 | - | - | $2,797 | |
TOTAL RECOMMENDED | $90,893 | $217,066 |
$86,296
1,995,369
kWh
|
$1,800
-
lb
|
$2,797 | ||
TOTAL IMPLEMENTED | $31,979 | $35,754 |
$29,182
660,478
kWh
|
- | $2,797 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs