Assessment Year 1999
Principal Product Cans
NAICS
n/a
SIC 3829: Measuring and Controlling Devices, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 110
Plant Area 62,000
ft2
Annual Production 400,000,000
pieces
Production Hrs. Annual 7,488
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $165,091 4,311,254
kWh
Electricity Demand $74,653 10,665
kW-mo/yr
Natural Gas $30,614 6,115
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $34,278 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,417

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,720 - $5,174
135,111
kWh
$1,546
-
kW-mo/yr
- -
02 2.4239: Eliminate or reduce compressed air usage $4,207 $1,400 $3,241
84,701
kWh
$966
-
kW-mo/yr
- -
03 2.6231: Utilize controls to operate equipment only when needed $2,405 $1,100 $1,778
46,600
kWh
$627
-
kW-mo/yr
- -
04 2.4239: Eliminate or reduce compressed air usage $1,977 - $1,522
39,859
kWh
$455
-
kW-mo/yr
- -
05 2.4133: Use most efficient type of electric motors $977 $1,439 $723
18,757
kWh
$254
-
kW-mo/yr
- -
06 2.3212: Optimize plant power factor $3,156 $5,517 - - $3,156 -
07 2.6231: Utilize controls to operate equipment only when needed $1,452 $2,550 $1,452
37,808
kWh
- - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $6,589 $21,750 $4,797
125,147
kWh
$1,792
-
kW-mo/yr
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $1,339 $1,339 $989
25,791
kWh
$350
-
kW-mo/yr
- -
10 3.5313: Increase amount of waste recovered for resale $2,606 - - - - $2,606
-
lb
11 3.5315: Lease / purchase baler; sell cardboard to recycler $2,850 $250 - - - $2,850
-
lb
TOTAL RECOMMENDED $34,278 $35,345 $19,676
513,774
kWh
$5,990
-
kW-mo/yr
$3,156 $5,456
-
lb
TOTAL IMPLEMENTED $26,417 $33,995 $17,898
467,174
kWh
$5,363
-
kW-mo/yr
$3,156 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs