Assessment Year | 1996 |
---|---|
Principal Product | Bread,Donut,Bun |
NAICS |
n/a
|
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 185 |
Plant Area |
200,000
ft2
|
Annual Production | 9,000,000
lb
|
Production Hrs. Annual | 5,460
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $255,340 | 4,465,709 |
kWh
|
$0.057 |
Electricity Demand | $99,842 | 9,516 |
kW-mo/yr
|
$10.49 |
Natural Gas | $108,231 | 44,292 |
MMBtu
|
$2.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,120 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,895 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,889 | $1,543 |
$1,450
22,567
kWh
|
$439
-
kW-mo/yr
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,109 | $1,393 |
$816
12,603
kWh
|
$293
-
kW-mo/yr
|
- | - | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $709 | $710 |
$374
5,569
kWh
|
$335
-
kW-mo/yr
|
- | - | |
04 | 2.4235: Remove or close off unneeded compressed air lines | $1,170 | $50 |
$949
14,654
kWh
|
$221
-
kW-mo/yr
|
- | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $1,590 | $6,792 |
$1,170
18,171
kWh
|
$420
-
kW-mo/yr
|
- | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,734 | - | - | - |
$3,734
-
MMBtu
|
- | |
07 | 2.6218: Turn off equipment when not in use | $4,221 | - |
$4,221
65,651
kWh
|
- | - | - | |
08 | 2.6231: Utilize controls to operate equipment only when needed | $3,473 | $1,625 |
$3,307
51,290
kWh
|
$166
-
kW-mo/yr
|
- | - | |
09 | 3.4155: Meter waste water | $7,225 | $4,500 | - | - | - |
$7,225
-
Tgal
|
|
TOTAL RECOMMENDED | $25,120 | $16,613 |
$12,287
190,505
kWh
|
$1,874
-
kW-mo/yr
|
$3,734
-
MMBtu
|
$7,225
-
Tgal
|
||
TOTAL IMPLEMENTED | $17,895 | $12,113 |
$12,287
190,505
kWh
|
$1,874
-
kW-mo/yr
|
$3,734
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs