| Assessment Year | 1996 |
|---|---|
| Principal Product | Electronic Weighing scales and Printers |
| NAICS |
n/a
|
| SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 70 |
| Plant Area |
160,000
ft2
|
| Annual Production | 10,000
pieces
|
| Production Hrs. Annual | 2,470
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $136,416 | 1,990,328 |
kWh
|
$0.069 |
| Electricity Demand | $77,079 | 6,317 |
kW-mo/yr
|
$12.20 |
| Natural Gas | $17,649 | 2,659 |
MMBtu
|
$6.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $50,519 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,282 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,008 | $70,980 |
$11,773
171,747
kWh
|
$10,235
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.7135: Install occupancy sensors | $4,085 | $11,200 |
$2,668
38,687
kWh
|
$1,417
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7135: Install occupancy sensors | $8,168 | $1,680 |
$5,335
77,667
kWh
|
$2,833
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,815 | $13,397 |
$10,739
116,647
kWh
|
- |
$(-4,924.0)
-
MMBtu
|
- | - | - | |
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $67 | $100 |
$67
879
kWh
|
- | - | - | - | - | |
| 06 | 2.4226: Use / purchase optimum sized compressor | $3,740 | $9,900 |
$2,373
34,584
kWh
|
$1,367
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,096 | $3,194 |
$1,069
15,533
kWh
|
$1,100
-
kW-mo/yr
|
$(-73.0)
-
MMBtu
|
- | - | - | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $662 | $2,200 |
$394
5,569
kWh
|
$268
-
kW-mo/yr
|
- | - | - | - | |
| 09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,218 | $6,800 | - | - | - | - |
$2,218
-
lb
|
- | |
| 10 | 3.8211: Convert to aqueous cleaning system | $1,660 | $5,561 | - | - | - |
$840
-
gal
|
- | $820 | |
| TOTAL RECOMMENDED | $50,519 | $125,012 |
$34,418
461,313
kWh
|
$17,220
-
kW-mo/yr
|
$(-4,997.0)
-
MMBtu
|
$840
-
gal
|
$2,218
-
lb
|
$820 | ||
| TOTAL IMPLEMENTED | $11,282 | $28,958 |
$13,179
152,110
kWh
|
$1,367
-
kW-mo/yr
|
$(-4,924.0)
-
MMBtu
|
$840
-
gal
|
- | $820 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs