Assessment Year 1995
Principal Product Computer Chips
NAICS
n/a
SIC 3674: Semiconductors and Related Devices
Sales Range $10
M
to 50
M
# of Employees 160
Plant Area 60,000
ft2
Annual Production 12,000,000
pieces
Production Hrs. Annual 2,000
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $333,393 3,508,206
kWh
Natural Gas $40,524 6,535
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,540 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,226

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4133: Use most efficient type of electric motors $1,169 $722 $1,169
12,309
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,319 $41,870 $10,319
108,441
kWh
03 2.7132: Install timers on light switches in little used areas $4,812 $3,400 $4,812
50,703
kWh
04 2.7135: Install occupancy sensors $116 $110 $116
1,172
kWh
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $973 $859 $973
10,258
kWh
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $11,161 $6,220 $11,161
117,526
kWh
07 2.6218: Turn off equipment when not in use $2,430 $2,760 $2,430
25,498
kWh
08 2.4221: Install compressor air intakes in coolest locations $272 $360 $272
2,931
kWh
09 2.4239: Eliminate or reduce compressed air usage $1,288 $1,670 $1,288
12,896
kWh
TOTAL RECOMMENDED $32,540 $57,971 $32,540
341,734
kWh
TOTAL IMPLEMENTED $7,226 $5,341 $7,226
76,201
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs