| Assessment Year | 1995 |
|---|---|
| Principal Product | Heat Treated |
| NAICS |
n/a
|
| SIC | 3398: Metal Heat Treating |
| Sales Range | $1 M to 5M |
| # of Employees | 21 |
| Plant Area |
25,000
ft2
|
| Annual Production | 10,700,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,112 | 1,097,597 |
kWh
|
$0.089 |
| Natural Gas | $99,652 | 31,520 |
MMBtu
|
$3.16 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,482 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,430 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $562 | $917 |
$562
6,155
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,734 | $8,540 |
$1,734
19,343
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $379 | $385 |
$379
4,396
kWh
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $8,513 | $18,500 | - |
$8,513
-
MMBtu
|
|
| 05 | 2.3212: Optimize plant power factor | $1,391 | $1,433 |
$1,391
-
kWh
|
- | |
| 06 | 2.6218: Turn off equipment when not in use | $3,604 | - |
$3,604
40,445
kWh
|
- | |
| 07 | 2.4226: Use / purchase optimum sized compressor | $2,430 | $11,500 |
$2,430
27,550
kWh
|
- | |
| 08 | 2.2628: Utilize a less expensive cooling method | $5,869 | $4,703 |
$5,869
65,651
kWh
|
- | |
| TOTAL RECOMMENDED | $24,482 | $45,978 |
$15,969
163,540
kWh
|
$8,513
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,430 | $11,500 |
$2,430
27,550
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs