Assessment Year | 2025 |
---|---|
Principal Product | Glass |
NAICS | 327211: Flat Glass Manufacturing |
SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 21 |
Plant Area |
90,000
ft2
|
Annual Production | 31,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $320,226 | 4,328,066 |
kWh
|
$0.074 |
Electricity Demand | $60,504 | 9,053 |
kW-mo/yr
|
$6.68 |
Electricity Fees | $1,276 | - |
|
- |
Natural Gas | $102,162 | 138,370 |
MMBtu
|
$0.74 |
TOTAL YEARLY COSTS | $484,168 | |||
RECOMMENDED SAVINGS* | $53,992 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $188 | $393 |
$188
2,546
kWh
|
- | - | |
02 | 2.9114: Use solar heat to make electricty | $16,332 | $130,462 |
$14,071
190,155
kWh
|
$2,261
-
kW-mo/yr
|
- | |
03 | 2.2437: Recover waste heat from equipment | $14,289 | $39,000 | - | - |
$14,289
-
MMBtu
|
|
04 | 2.2515: Use optimum thickness insulation | $23,183 | $32,000 | - | - |
$23,183
-
MMBtu
|
|
TOTAL RECOMMENDED | $53,992 | $201,855 |
$14,259
192,701
kWh
|
$2,261
-
kW-mo/yr
|
$37,472
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs