| Assessment Year | 1994 |
|---|---|
| Principal Product | Roofing Felts |
| NAICS |
n/a
|
| SIC | 2952: Asphalt Felts and Coatings |
| Sales Range | $10 M to 50M |
| # of Employees | 32 |
| Plant Area |
65,000
ft2
|
| Annual Production | 75,000
ton
|
| Production Hrs. Annual | 8,640
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $157,349 | 1,660,023 |
kWh
|
$0.095 |
| Natural Gas | $72,391 | 18,538 |
MMBtu
|
$3.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,534 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,193 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $617 | $185 |
$617
6,448
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $576 | $761 |
$576
6,155
kWh
|
- | |
| 03 | 2.2515: Use optimum thickness insulation | $1,262 | $773 | - |
$1,262
-
MMBtu
|
|
| 04 | 2.1213: Direct warmest air to combustion intake | $11,628 | $9,140 | - |
$11,628
-
MMBtu
|
|
| 05 | 2.1134: Eliminate leaks in combustible gas lines | $386 | $300 | - |
$386
-
MMBtu
|
|
| 06 | 2.2511: Insulate bare equipment | $917 | $2,200 | - |
$917
-
MMBtu
|
|
| 07 | 2.4221: Install compressor air intakes in coolest locations | $1,148 | $380 |
$1,148
12,016
kWh
|
- | |
| TOTAL RECOMMENDED | $16,534 | $13,739 |
$2,341
24,619
kWh
|
$14,193
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $14,193 | $12,413 | - |
$14,193
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs