ITAC Assessment: SD0698
ITAC logo
ITAC Assessment: SD0698
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Fabric Printing
NAICS 313310: Textile and Fabric Finishing Mills
SIC 2269: Finishers of Textiles, Not elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 16
Plant Area 94,000
ft2
Annual Production 3,000
thousand feet
Production Hrs. Annual 2,250
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $51,603 250,080
kWh
Electricity Demand $40,297 2,856
kW-mo/yr
Electricity Fees $12,894 -
Natural Gas $84,298 9,686
MMBtu
TOTAL YEARLY COSTS $189,092
RECOMMENDED SAVINGS* $142,373 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2121: Increase amount of condensate returned $19,217 $12,000 $14,080
68,252
kWh
$5,136
-
kW-mo/yr
-
02 2.2414: Use waste heat from hot flue gases to preheat $1,975 $1,671 - - $1,975
-
MMBtu
03 2.2135: Repair and eliminate steam leaks $2,690 $600 - - $2,690
-
MMBtu
04 2.3131: Reschedule plant operations or reduce load to avoid peaks $1,200 - - $1,200
-
kW-mo/yr
-
05 2.3132: Recharge batteries on during off-peak demand periods $2,048 - - $2,048
-
kW-mo/yr
-
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $100 $847 $72
350
kWh
$28
-
kW-mo/yr
-
07 2.4223: Install direct acting units in place of compressed air pressure system in safety system $1,728 $3,200 $1,728
8,376
kWh
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $8,172 $12,660 $5,988
29,025
kWh
$2,184
-
kW-mo/yr
-
09 2.4133: Use most efficient type of electric motors $16,055 $85,261 $10,802
52,360
kWh
$5,253
-
kW-mo/yr
-
10 2.9114: Use solar heat to make electricty $67,845 $178,000 $52,607
255,000
kWh
$15,239
-
kW-mo/yr
-
11 2.3141: Use battery storage for demand control $21,343 $76,800 $(-2,785.1)
(-13,500)
kWh
$24,128
-
kW-mo/yr
-
TOTAL RECOMMENDED $142,373 $371,039 $82,492
399,863
kWh
$55,217
-
kW-mo/yr
$4,665
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs