| Assessment Year | 2026 |
|---|---|
| Principal Product | Commercial Printing |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2761: Manifold Business Forms |
| Sales Range | $10 M to 50M |
| # of Employees | 52 |
| Plant Area |
50,000
ft2
|
| Annual Production | 100,000,000
units
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $119,917 | 985,642 |
kWh
|
$0.12 |
| Electricity Demand | $173,338 | 4,247 |
kW-mo/yr
|
$40.81 |
| Electricity Fees | $10,445 | - |
|
- |
| TOTAL YEARLY COSTS | $303,700 | |||
| RECOMMENDED SAVINGS* | $561,823 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,232 | - |
$2,232
18,343
kWh
|
- | |
| 02 | 2.9114: Use solar heat to make electricty | $190,274 | $384,556 |
$78,618
646,000
kWh
|
$111,656
-
kW-mo/yr
|
|
| 03 | 2.3141: Use battery storage for demand control | $172,708 | $85,941 |
$(-4,081.0)
(-33,529)
kWh
|
$176,789
-
kW-mo/yr
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $55,458 | $67,347 |
$26,752
219,816
kWh
|
$28,706
-
kW-mo/yr
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,121 | $3,568 |
$1,729
14,210
kWh
|
$1,392
-
kW-mo/yr
|
|
| 06 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $3,872 | $4,600 |
$3,872
31,813
kWh
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $396 | $1,694 |
$209
1,714
kWh
|
$187
-
kW-mo/yr
|
|
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $45,060 | $11,400 |
$24,967
205,150
kWh
|
$20,093
-
kW-mo/yr
|
|
| 09 | 2.3132: Recharge batteries on during off-peak demand periods | $14,692 | - | - |
$14,692
-
kW-mo/yr
|
|
| 10 | 2.7234: Use heat pump for space conditioning | $74,010 | $21,175 |
$41,007
336,950
kWh
|
$33,003
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $561,823 | $580,281 |
$175,305
1,440,467
kWh
|
$386,518
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs