ITAC Assessment: SD0688
ITAC logo
ITAC Assessment: SD0688
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Engine blades and disks
NAICS 336412: Aircraft Engine and Engine Parts Manufacturing
SIC 3724: Aircraft Engines and Engine Parts
Sales Range $50
M
to 100
M
# of Employees 366
Plant Area 160,000
ft2
Annual Production 55,000
units
Production Hrs. Annual 7,200
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $584,251 3,523,049
kWh
Electricity Demand $665,304 10,282
kW-mo/yr
Electricity Fees $5,026 -
TOTAL YEARLY COSTS $1,254,581
RECOMMENDED SAVINGS* $5,920,199 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Usage Savings Ancillary Material Cost Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $169,677 $26,436 $102,805
620,051
kWh
$66,872
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $168 $254 $102
615
kWh
$66
-
kW-mo/yr
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $46,564 $46,160 $28,212
170,160
kWh
$18,352
-
kW-mo/yr
- -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,437 $10,800 $4,775
28,798
kWh
$2,662
-
kW-mo/yr
- -
05 2.9114: Use solar heat to make electricty $3,672,174 $4,969,681 $1,384,158
8,348,360
kWh
$2,288,016
-
kW-mo/yr
- -
06 2.3141: Use battery storage for demand control $884,812 $1,273,750 $(-37,305.0)
(-225,000)
kWh
$922,117
-
kW-mo/yr
- -
07 2.4231: Reduce the pressure of compressed air to the minimum required $95,152 - $95,152
573,893
kWh
- - -
08 4.212: Adopt in-house material generation $361,127 $464,200 $(-87,433.0)
(-527,342)
kWh
- - $448,560
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,480 $2,885 $2,816
16,986
kWh
$2,664
-
kW-mo/yr
- -
10 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $6,467 $6,752 $3,918
23,633
kWh
$2,549
-
kW-mo/yr
- -
11 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $19,402 $15,192 $11,755
70,900
kWh
$7,647
-
kW-mo/yr
- -
12 2.7234: Use heat pump for space conditioning $292,020 $114,400 $201,944
1,218,000
kWh
$90,076
-
kW-mo/yr
- -
13 2.4221: Install compressor air intakes in coolest locations $279,031 $9,550 $52,287
315,360
kWh
$226,744
-
kW-mo/yr
- -
14 2.2695: Use cascade system of recirculating during cold weather to avoid sub-cooling $18,033 $2,250 - - $18,033
-
Tgal
-
15 2.4133: Use most efficient type of electric motors $62,655 $56,920 $30,702
185,174
kWh
$31,953
-
kW-mo/yr
- -
TOTAL RECOMMENDED $5,920,199 $6,999,230 $1,793,888
10,819,588
kWh
$3,659,718
-
kW-mo/yr
$18,033
-
Tgal
$448,560
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Usage Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs